The EC-20 has a proprietary cast iron eutectic heat exchang-
er that is resistant to thermal shock and corrosion. The cast
iron is flexible and resilient which allows for lower temperature
operation especially with outdoor reset controls. This yields
significant energy savings.
The EC Series efficiency is a result of the boiler’s unique
three pass design heat exchanger with specially designed
baffles for maximum heat exchanger contact, flue turbulation
and heat transfer. AFUE is 86.5%.
The three pass design of the Eutectic makes it very quiet too.
There is plenty of room for thermal expansion of the flue
gasses to keep burner and flame noise to a very minimum. It
is easy to clean, the door is reversible, the baffles are remov-
able and brushing the flueways is a snap.
The Eutectic boiler, like other Slant/Fin oil boilers, will operate
cleanly under all the different operating conditions. We’ve
done the testing and have matched burners and components
to this boiler to make sure the boiler will stay running clean
after you leave the job.
Features
Quiet
86.5% Efficiency
Three pass heat e
xchanger maximizes heat transfer
Easy to clean, operates clean
Resilient, flexible, Eutectic cast iron
Resistant to thermal shoc
k and corrosion
Outdoor reset compatible with low water temps
Hinged, reversible swing out door for fast, easy cleaning
Available with Riello burners
Standard operating control, Honeywell 7248C
Oil-Fired 217,000–350,000 BTU Models Up To 86.5% efficiency
EC-20 Oil-Fired Boiler
E
UTECTIC
EC
-
20
A superior cast-iron, three pass, oil-fired boiler
Optional Thermatic Control
Total System management and boiler control, provides greater
comfort and utmost in fuel conservation. Reduces cycling.
The EC Series efficiency is a result of the boiler’s
unique three pass Eutectic cast iron heat
e
xchanger. The three pass design
along with 4 inches of insu-
lation make it the quietest
boiler in its class. The
Eutectic heat exchanger
allows for plenty of thermal
expansion of the
flue gasses to
keep the flame
noise to a minimum.